Skip to main content

XAICMT — Motion Threshold

Configures the accelerometer motion threshold used for standard motion detection.

Format

  • Query: >QXAICMT<
  • Set: >SXAICMT{VALUE}<
  • Reset to default: >SXAICMT<
  • Response: >RXAICMT{VALUE}<
FieldRangeDescription
VALUE10-500Threshold in milli-g (mg). Default: 35 mg

Examples

>QXAICMT<
>RXAICMT35<

>SXAICMT50<
>SXAICMT<
  • F12 — standard motion detected
  • Extended tag AP

Defaults and Limits

  • Value range: 10 to 500 mg.
  • Default value: 35 mg.
  • Out-of-range values are rejected.