XAICMT — Motion Threshold
Configures the accelerometer motion threshold used for standard motion detection.
Format
- Query:
>QXAICMT< - Set:
>SXAICMT{VALUE}< - Reset to default:
>SXAICMT< - Response:
>RXAICMT{VALUE}<
| Field | Range | Description |
|---|---|---|
VALUE | 10-500 | Threshold in milli-g (mg). Default: 35 mg |
Examples
>QXAICMT<
>RXAICMT35<
>SXAICMT50<
>SXAICMT<
Related Signals
F12— standard motion detected- Extended tag
AP
Defaults and Limits
- Value range:
10to500mg. - Default value:
35mg. - Out-of-range values are rejected.